BD Diesel Air Intake Shutdown
BD Diesel 1036703 Positive Air Shut-Off for Ford Power Stroke - 6.7L 2011-2014
BD Diesel 1036701 Positive Air Shut-Off for Ford Power Stroke - 6.0L 2003-2007
BD Diesel 1036720 Positive Air Shut-Off for 2003-2007 Dodge 5.9L Cummins
BD Diesel 1036703-M Positive Air Shut-Off Manual Control - Ford 6.7L Power Stroke
BD Diesel 1036701-M Positive Air Shut-Off Manual Control Ford 6.0L Powerstroke 2003-2007
BD Diesel 1036713-M Positive Air Shut-Off Manual Control for 2011-2016 Duramax 6.6L
BD Diesel 1036712-M Positive Air Shut-Off Manual Valve Duramax LLY/LBZ/LMM 2004.5-2010
BD Diesel 1036724-M Positive Air Shutdown Valve for Emergency Engine Shutoff
BD Diesel 1036732 Positive Air Shut-Off Intake Emergency Shutdown Valve - 3.5in
BD Diesel 1036733 Positive Air Shut-Off Intake Emergency Shutdown Valve - 4.0in
BD Diesel 1036730 Positive Air Shut-Off Intake Emergency Shutdown Valve - 3.0in
BD Diesel 1036713 Positive Air Shut-Off for 2011-2016 Silverado/Sierra 6.6L Duramax
BD Diesel 1036712 Positive Air Shut-Off for Chevy 2004.5-2010 LLY/LBZ/LMM
BD Diesel 1036724 Positive Air Shutdown Valve for Diesel Engines
BD Diesel 1036720-M Positive Air Shut-Off Manual Valve Dodge 5.9L Cummins
BD Diesel 1036753 E-PAS Electronic Positive Air Shut-Off Cummins - 6.7L 2019-2024
BD Diesel 1036755 E-PAS Electronic Positive Air Shut-Off 6.7L Power Stroke Ford 2011-2019
BD Diesel 1036754 E-PAS Electronic Positive Air Shutdown Ford 6.4L Power Stroke 2008-2010
BD Diesel 1036751 E-PAS Electronic Positive Air Shut-Off Cummins - 6.7L 2010-2018
BD Diesel 1036758 E-PAS Electronic Positive Air Shut-Off for Chevy 6.6L Duramax
BD Diesel 1036750 E-PAS Electronic Positive Air Shutdown Dodge 6.7L Cummins 2007-2010
BD Diesel 1036760 E-PAS Electronic Positive Air Shut-Off 2016-2023 Chevy Colorado GMC Canyon 2.8L Duramax
BD Diesel 1036772 E-PAS Electronic Positive Air Shut-Off Volvo D13 Mack MP8 2017-2023
BD Diesel 1036771 E-PAS Electronic Positive Air Shut-Off Detroit Diesel DD13 DD15 DD16
BD Diesel 1036761 E-PAS Emergency Positive Air Shut-Off for 2017-2023 Duramax L5P
BD Diesel Positive Air Shutdown: Emergency Engine Protection You Can Trust
For diesel engines operating in high-risk environments, an air intake shutdown system is one of the most critical safety components you can install. BD Diesel — a brand with roots stretching back to 1972 — has brought the same engineering philosophy that defined its legendary exhaust brakes to its line of air intake shutdown products, delivering a solution purpose-built for demanding diesel applications.
What Is a Positive Air Shutdown and Why Does It Matter?
Diesel engines, unlike gasoline engines, cannot be shut down simply by cutting the fuel supply when external hydrocarbons enter the intake stream. Diesel engine runaway occurs when the engine begins feeding off unintended fuel sources — such as crankcase vapors, natural gas leaks, or other airborne hydrocarbons — causing the engine to overspeed uncontrollably and potentially suffer catastrophic failure. The only reliable remedy is to starve the engine of air entirely.
Industries such as mining, oil refinery work, forestry, mobile welding, and fuel hauling often mandate emergency engine shutdown systems for exactly this reason. BD Diesel's Positive Air Shutdown (PAS) addresses this need head-on with a system engineered for real-world, heavy-duty use.
BD Diesel's Positive Air Shutdown (PAS): How It Works
BD Diesel's PAS system places an inline butterfly valve directly in the air intake line. When triggered, a heavy-duty electrical solenoid activates a locked safety cam, closing the valve and shutting the engine down within seconds. The compact butterfly valve design is a clear differentiator: it reduces the total number of components and the overall footprint compared to guillotine-style competitors, adding only about 6 inches of length and 3 inches of height above the pipe.
BD's PAS kits are available in two control configurations:
- Automatic (Electronic Overspeed Protection): Includes an overspeed electronics module that monitors engine RPM and triggers the shutdown automatically if a runaway condition is detected — no driver intervention required.
- Manual: A straightforward on/off switch for operators who need direct, hands-on control of the emergency shutoff.
Both variants are built in multiple intake diameters — including 2.5", 3.0", and 4.0" — to accommodate a wide range of heavy-duty diesel applications from Duramax-equipped Chevy/GMC trucks to Ford Powerstroke and Cummins-powered platforms.
Built for Durability and Easy Installation
BD doesn't cut corners on materials. Every PAS unit features aluminum and stainless steel components paired with weatherproof electrical connectors to resist corrosion in the harsh environments where these systems are most needed. Installation is straightforward: BD's innovative bead boot locks keep the hoses securely in place without requiring any welding, and boots and clamps are included in the kit.
Why BD Diesel for Air Intake Shutdown?
BD Diesel has spent decades engineering safety and performance solutions for the diesel market. The same company that introduced the first exhaust brake for diesel pickup trucks now applies that legacy of innovation to emergency engine protection. Whether you're running an oilfield service truck, a forestry vehicle, or any diesel that operates around combustible atmospheres, BD Diesel's Positive Air Shutdown system is a compact, proven, and code-ready solution that can mean the difference between a close call and a catastrophic loss.